1 SC-GH SERIES HIGH EFFICIENCY GAS FIRED CONVECTION STEAMER INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN CO
10 INSTALLATION (Continued) WATER CONDITIONING: It is important that the water supplied to the generator be softened to no more than 2.0 grains of
11 3.0 PERFORMANCE CHECK CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. Once the st
12 4.0 OPERATION INSTRUCTIONS CAUTION: If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been
13 4.0 OPERATION INSTRUCTIONS (Continued) WARNING: In the event you smell gas, shut down equipment at the main shut off valve and contact the local
14 Ignition Light When lit, indicates ignition at the pilot. NOTE: Each cooking compartment has its own steam generator and controls and can be op
15 4.0 OPERATION INSTRUCTIONS (Continued) PREPARATION Prepare vegetables, fruits, meats, seafood and poultry normally by cleaning, separating, cu
16 5.0 MAINTENANCE NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs. WARNING:
17 5.0 MAINTENANCE (Continued) WEEKLY (or more often if necessary): 1. Clean exterior with a damp cloth and polish with a soft dry cloth. 2. Us
18 5.0 MAINTENANCE (Continued) Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing the surface wi
19 6.0 DELIMING PROCEDURE CAUTION: Read and follow instructions on the CLR bottle. Use plastic or rubber gloves to avoid skin contact. If CLR co
2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION This is the safety alert symbol. It is used to alert you to potential personal injury hazards. O
20 7.0 TROUBLESHOOTING Burners do not come on: 1. Gas supply to unit is “OFF”. 2. Power Switch is not turned “ON”. 3. Steam generator probe n
21 7.0 TROUBLESHOOTING (Continued) Water accumulates in the compartment: 1. Compartment drain clogged. Water flows into drain during shut down:
3 TABLE OF CONTENTS DESCRIPTION PAGE 1.0 Service Connections ...
4 1.0 SERVICE CONNECTIONS * SC-10GH ONLY
5 2.0 INSTALLATION WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made. Installation must
6 2.0 INSTALLATION (Continued) 2.1 EXHAUST FANS AND CANOPIES: Canopies are set over ranges, ovens, kettles, etc., for ventilation purposes. It i
7 2.0 INSTALLATION (Continued) To Install: 1. Uncrate carefully. Report any freight damage to the freight company immediately. 2. Set the uni
8 2.0 INSTALLATION (Continued) 1.0 The Serial and Rating Plate on the unit indicates the type of gas your unit is equipped to burn. DO NOT connec
9 2.0 INSTALLATION (Continued) PLUMBING CONNECTIONS: Two water lines are provided. Connect water supply lines to the 3/8" copper tubes at