Page 1 - SC-GH SERIES

1 SC-GH SERIES HIGH EFFICIENCY GAS FIRED CONVECTION STEAMER INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN CO

Page 2

10 INSTALLATION (Continued) WATER CONDITIONING: It is important that the water supplied to the generator be softened to no more than 2.0 grains of

Page 3 - TABLE OF CONTENTS

11 3.0 PERFORMANCE CHECK CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance. Once the st

Page 4 - 1.0 SERVICE CONNECTIONS

12 4.0 OPERATION INSTRUCTIONS CAUTION: If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been

Page 5

13 4.0 OPERATION INSTRUCTIONS (Continued) WARNING: In the event you smell gas, shut down equipment at the main shut off valve and contact the local

Page 6

14 Ignition Light When lit, indicates ignition at the pilot. NOTE: Each cooking compartment has its own steam generator and controls and can be op

Page 7

15 4.0 OPERATION INSTRUCTIONS (Continued) PREPARATION Prepare vegetables, fruits, meats, seafood and poultry normally by cleaning, separating, cu

Page 8

16 5.0 MAINTENANCE NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs. WARNING:

Page 9

17 5.0 MAINTENANCE (Continued) WEEKLY (or more often if necessary): 1. Clean exterior with a damp cloth and polish with a soft dry cloth. 2. Us

Page 10

18 5.0 MAINTENANCE (Continued) Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing the surface wi

Page 11

19 6.0 DELIMING PROCEDURE CAUTION: Read and follow instructions on the CLR bottle. Use plastic or rubber gloves to avoid skin contact. If CLR co

Page 12

2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION This is the safety alert symbol. It is used to alert you to potential personal injury hazards. O

Page 13

20 7.0 TROUBLESHOOTING Burners do not come on: 1. Gas supply to unit is “OFF”. 2. Power Switch is not turned “ON”. 3. Steam generator probe n

Page 14

21 7.0 TROUBLESHOOTING (Continued) Water accumulates in the compartment: 1. Compartment drain clogged. Water flows into drain during shut down:

Page 15

3 TABLE OF CONTENTS DESCRIPTION PAGE 1.0 Service Connections ...

Page 16

4 1.0 SERVICE CONNECTIONS * SC-10GH ONLY

Page 17

5 2.0 INSTALLATION WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made. Installation must

Page 18

6 2.0 INSTALLATION (Continued) 2.1 EXHAUST FANS AND CANOPIES: Canopies are set over ranges, ovens, kettles, etc., for ventilation purposes. It i

Page 19

7 2.0 INSTALLATION (Continued) To Install: 1. Uncrate carefully. Report any freight damage to the freight company immediately. 2. Set the uni

Page 20

8 2.0 INSTALLATION (Continued) 1.0 The Serial and Rating Plate on the unit indicates the type of gas your unit is equipped to burn. DO NOT connec

Page 21

9 2.0 INSTALLATION (Continued) PLUMBING CONNECTIONS: Two water lines are provided. Connect water supply lines to the 3/8" copper tubes at